A-A-52480A
2.3 Conduit classes. Push-pull control assemblies will have one of the following two different
classes of wire conduit, class I or class II.
3. SALIENT CHARACTERISTICS.
3.1 Materials. Unless specified herein, materials shall be in accordance with the manufacturer's
material specifications. The use of recovered material made in compliance with regulatory
requirements is acceptable providing that all requirements of this CID are met (see 4).
3.2 Design and construction. The general design and construction features of the push-pull type
control assemblies are shown in figures 1 through 4. The four different control assemblies
consist primarily of various styles of control handles attached to various locking mechanisms and
class of conduit. A plunger rod shall permanently and rigidly attach the handle to a core wire
which can be actuated backwards and forwards inside a flexible conduit. The conduit shall be in
the form of a closed helix. When specified (see 7.3), the conduit shall be provided with a plastic
inner lining or encased in a plastic or rubber sleeve. The plunger rod shall be able to slide freely
inside a threaded mounting adapter that is attached to a guide tube. Mounting hardware shall be
provided with each assembly. Detailed and specific features and dimensions will be determined
according to specific applications and as specified in Table I.
3.2.1 Configuration. Many of the general design features (handles, styles, cover plates, conduit
classes, etc.) shown in any of the four figures may be installed on different control assemblies.
Handle style 2 (see figure 2) may have a horizontal or vertical locking position.
3.3 Performance. All control assemblies (figures 1 through 4) shall be capable of operating
satisfactorily in a temperature range of minus (-) 65 to plus (+) 115 degrees Fahrenheit (�F), with
up to 30 pounds (lb) of push-pull actuating force. Unless otherwise specified (see 7.3), control
handles shall withstand the steady, gradually applied pull load that is given for each control
assembly type without separation from or damage to the assembly. They shall operate smoothly
throughout the entire travel length without binding. The conduits shall show no permanent set
from a minimum bend radius of 3 inches (in.).
3.3.1 Friction lock (Type I). Type I assembly (figure 1) shall require 3 to 8 lb to adjust and be
able to withstand a maximum pull load of 120 lb. With a minimum conduit bend radius of 3 in.,
the assembly shall function smoothly with up to a 20 lb push-pull actuating force.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business